RBz 1-6 Intrinsically safe electro-hydraulic block

Decription

Hydraulic splitter controlled Electrically or mechanically installed in machines and hydraulic devices,
which operate in underground mines in potentially explosive atmospheres.
 
  • Modular construction
  • Designed to operate in potentially explosive atmospheres
  • Electric or mechanical control
  • Liquid – oil, water-oil emulsion

Specification

Electrical parameters

   

- Electric control :         

 

control unit type ZES 40     

- Power supply:

 

12 V DC ± 15%

- Coil resistance:

  

126 ± 10 Ω

Operating conditions

   

- KV flowrate according to DIN IEC 53

 

15,8 l/min for water-oil emulsion

- Ambient temperature

 

5 ÷ 65ºC

- Relative humidity

 

do 95 %

- Working liquid

 

olej hydrauliczny, emulsja olejowo-wodna

- Required/recommended filtration level

 

40/25 µm

- Nominal pressure

 

32 MPa

- Maximum pressure

 

35 MPa

Mechanical parameters

   

Weight

 

n × 6,8 kg

Dimensions

 

(n × 40,5 + 40) × 150 × 268 mm

   

n = 1 ÷ 6

Gallery