Analogue inputs 3
Frequency band limited by 500Hz mode, threefold 0-206.5Hz
Anti-aliasing filter 1kHz mode, twofold 0- 413.0Hz
High-pass filter available between 0.1 Hz and 1 Hz
Processing resolution 24-bit
Signal-to-noise ratio (SNR) 96 db @1 kHz
Sampling Rate 500 Hz or 1 kHz
Programmable low noise level amplifier x2, x4, x8, x16, x32, x64, x128
Transmission type DTSS digital transmission of seismic signals, 3 components per one line
Transmission range SP/DTSS up to 10 km
SD/DTSS up to 2,5 or 5 km
Operating temperature 0°C up to +50°C
Casing protection parameter IP54
Dimensions 19 x 16 x 6.5 (cm)
Weight 4kg
Dedicated sensors SG3u, GVu, GVd, GHa, SP-5.28/E
Dedicated systems ARAMIS M/E, digital ARES*