SV*/DTSS Seismometer

Description

Intrinsically safe single-component seismometer SV*/DTSS of the ARAMIS M/E system

Key features:

- seismic signal measurement module of the ARAMIS M/E or INGEO system,

- integrated low-frequency GS-1 seismometer by Geospace with a digital transceiver module in a shared housing,

- conversion of analog signal from the seismometer into digital form,

- data transmission to the surface digital receiver module OCGA or underground OCGD local data concentrator LKP,

- synchronization of the clock generator for A/C converters,

- electrical locking and functional testing of the seismometer,

- intrinsically safe device of Group I, Category M1 with protection level "ia", compatible with a measuring concentrator of level "ia" or "ib".

Specification

Number of recorded components

One: Z

Natural frequency of low-frequency GS-1-LF sensors

1.0 Hz ±10%

Permissible tilt angle from vertical during operation

± 7.5o

Sensitivity

118 V/m/s

Mass of moving coil in each sensor

700g ±5%

Maximum coil displacement in each sensor

6.35 mm P-P

Shock resistance

50G

Transmitted frequency band (without probe) – limited by anti-aliasing filter:

500 Hz mode – 0-206.5 Hz

2 kHz mode – 0-826.0 Hz

Configurable high-pass filter

From 0.1 to 1 Hz with option to disable

A/C converter resolution

24 bits

Processing dynamic range (total SNR)

130 dB @ 250 Hz

Sampling frequency

500 Hz, 2 kHz

Adjustable gain

x2, x4, x8, x16, x32, x64, x128

Transmission type / Synchronization / Special application conditions

DTSS – pulse digital transmission via telecom power line

Transmission range

10 km for OCGA or 5 km for OCGD

IP protection rating

IP65

Additional functions

electrical locking, seismometer test

Mounting method

SVd – anchor, floor

SVu – anchor, ceiling

SVf – feet, floor

© crystalis.pl  All rights reserved.