Underground station SD/DTSS transmitting seismic data of the ARAMIS M/E system.
It enables digital transmission of analog signals obtained from geophone sensors or seismometers installed in the mine's underground to the seismic stations. Up to 8 SD/DTSS stations can be installed.
After power is switched on, the underground station operates unattended, reading the data recorded in the connected NSGA transmitters and forwarding the data to the recording computer.
The SD/DTSS station is an intrinsically safe device of Group I, Category M1.
Specification
Electrical Parameters
Supply voltage
2 x 12 V
Maximum current consumption
2 x 750 mA
Intrinsic Safety Parameters
Connector Z1, Z2
Maximum input voltage
Ui = 13.6 V
Connector P1
Maximum output voltage
Uo = 25.2 V
Maximum output current
Io = 62 mA
Maximum output power
Po = 1.15 W
Maximum output inductance
Lo = 20 mH
Maximum output capacitance
Co = 0.86 μF
Transmission Parameters
Type of transmission
digital, bidirectional
Connections
Cable entries
PG16, 2 x PG11
Connector
fiber optic; BIFOC 6 1 332 2 BP or BIFOC 9 1 332 2 BP