NSGA Transmitter

Description

The NSGA transmitter is used to collect data from geophone sensors or seismometers, convert it into digital form, and transmit it to the surface station SP/DTSS or the underground station SD/DTSS.

The transmitter is a component of the DTSS digital seismic signal transmission system of the ARAMIS M/E system.

The NSGA transmitter is an intrinsically safe device of Group I, Category M1.

The signal inputs of the NSGA transmitter can be connected to the following vibration sensors:
- up to three geophone probes: GVu, GVd, or GHa,
- one triaxial probe: SG3/xxx or SG3/xxx-P,
- up to three seismic sensors: CS/DTSS.

Specification

Electrical Parameters (Power Line)
Maximum input voltage   Ui = 35 V
Maximum input current   Ii = 78 mA
Maximum input power   Pi = 2 W
Maximum internal inductance   Li – negligible
Maximum internal capacitance   Ci – negligible
Minimum supply voltage   13 V DC
Transmitter current consumption   ≤ 25 mA
Transmission Parameters
Type of transmission   digital, bidirectional
Number of input channels   3
Mechanical Parameters
Protection rating   IP54
Ambient temperature   0°C – 40°C
Additional Functions
- Sensor connection test function    