NSGA Transmitter

Description

The NSGA transmitter is used to collect data from geophone sensors or seismometers, convert it into digital form, and transmit it to the surface station SP/DTSS or the underground station SD/DTSS.

The transmitter is a component of the DTSS digital seismic signal transmission system of the ARAMIS M/E system.

The NSGA transmitter is an intrinsically safe device of Group I, Category M1.

The signal inputs of the NSGA transmitter can be connected to the following vibration sensors:
- up to three geophone probes: GVu, GVd, or GHa,
- one triaxial probe: SG3/xxx or SG3/xxx-P,
- up to three seismic sensors: CS/DTSS.

Specification

Electrical Parameters (Power Line)
Maximum input voltage   Ui = 35 V
Maximum input current   Ii = 78 mA
Maximum input power   Pi = 2 W
Maximum internal inductance   Li – negligible
Maximum internal capacitance   Ci – negligible
Minimum supply voltage   13 V DC
Transmitter current consumption   ≤ 25 mA
Transmission Parameters
Type of transmission   digital, bidirectional
Number of input channels   3
Mechanical Parameters
Protection rating   IP54
Ambient temperature   0°C – 40°C
Additional Functions
- Sensor connection test function    

© crystalis.pl  All rights reserved. 

We use cookies on our website. Some of them are essential for the operation of the site, while others help us to improve this site and the user experience (tracking cookies). You can decide for yourself whether you want to allow cookies or not. Please note that if you reject them, you may not be able to use all the functionalities of the site.