MP N/O Measurement module

Description

The MP N/O measurement module is used for processing and digitally transmitting signals from geophone sensors or seismometers to the local measurement concentrator LKP using DTSS transmission. The module is designed for sampling signals from geophone probes and performing analog-to-digital (A/D) conversion synchronously with the reference clock signal, at a frequency required for signal sampling with delay compensation caused by transmission lines of different lengths.

The module can operate in a configuration with or without an exciter. In a system containing an exciter, the input power supply of the MP N/O module working with the WZB exciter is supplied with voltage from an intrinsically safe power supply, and the exciter control output is connected to the WZB exciter.

The main functions of the MP N/O module are:

  • processing analog signals from the geophone probe into digital signals,
  • collecting digital data and forming a frame,
  • transmitting data to the OCGD or OCGA digital receiver module,
  • synchronizing the clock generator for the A/D converters,
  • providing an exciter control signal (only for configurations with an exciter control output).

The MP N/O module is an intrinsically safe device of Group I, Category M1, with protection level “ia”, which can work with a measurement concentrator with protection level “ia” or “ib”.

Specification

Maximum current consumption   35 mA

Bandwidth limited by anti-aliasing filter

 

250 Hz mode – 0 – 103.25 Hz
500 Hz mode – 0 – 206.5 Hz
1 kHz mode – 0 – 413.0 Hz
2 kHz mode – 0 – 826.0 Hz

High-pass filter

 

from 0.1 Hz to 1 Hz, can be disabled

Processing resolution

 

24 bits

Signal-to-noise ratio (SNR)

 

130 dB @ 250 Hz

Sampling frequency

 

250 Hz, 500 Hz, 1 kHz, 2 kHz

Adjustable gain

 

x2, x4, x8, x16, x32, x64, x128

Transmission type

 

DTSS – pulse digital transmission via
telecommunication power line

Transmission range

 

- for SP/DTSS up to 10 km,

- for SD/DTSS up to 5 km

Ambient temperature

 

0°C to +50°C

Enclosure protection degree

 

IP54

Dimensions

 

19 x 16 x 6.5 (cm)

Weight

 

4 kg

© crystalis.pl  All rights reserved. 

We use cookies on our website. Some of them are essential for the operation of the site, while others help us to improve this site and the user experience (tracking cookies). You can decide for yourself whether you want to allow cookies or not. Please note that if you reject them, you may not be able to use all the functionalities of the site.