Type of Explosion-Proof Design
|
|
Associated apparatus intended for operation in explosive atmospheres
|
|
Special Marking of Explosion Protection
|
|
I M1 Ex ia op is I Ma
|
|
ATEX Certificate Number
|
|
OBAC 08 ATEX 017X
|
|
Supply Voltage (Un)
|
|
11 – 17 VDC
|
|
Maximum Current Consumption (Imax)
|
|
690 mA
|
|
Communication Interfaces for Interfacing Devices
|
|
|
|
RS485
|
|
|
|
RS485
|
|
|
|
Twisted-pair cable UT5, 100 Mbit/s
|
- Fiber Optic Ethernet Interface
|
|
Single-mode fiber, 100 Mbit/s, SC or FC connector
|
|
RS485 Interface Parameters
|
|
|
|
115200 kb/s
|
|
|
|
“ia”
|
- Number of devices on shared line
|
|
4
|
- Maximum transmission range
|
|
1000 m
|
|
Ethernet Interface Parameters (Twisted Pair)
|
|
|
|
1
|
|
|
|
RJ45
|
|
|
|
100 Mbit/s
|
|
|
|
100 m
|
|
|
|
“op is”
|
|
Ethernet Interface Parameters (Fiber Optic)
|
|
|
|
1
|
|
|
|
SC, FC
|
|
|
|
Single-mode
|
|
|
|
100 Mbit/s
|
|
|
|
20 km
|
|
|
|
“op is”
|
|
Power Input
|
|
Uᵢ = 17 V, Lᵢ ≈ 0 µH, Cᵢ ≈ 0 µF
|
|
Power Outputs (+12 VDC, GND)
|
|
Intrinsically safe circuits at the safety level guaranteed by the power supply:
Uo = Output voltage of the power supply
Io = Output current of the power supply
Lo = Inductance of power supply – cable inductance (Lc)
Co = Capacitance of power supply – cable capacitance (Cc)
|
|
Approval According to Certificate
|
|
The ZK EX Communication Unit is intended for use in underground workings of mining facilities in areas endangered by methane and coal dust explosions.
|
- Maximum Cross-Section of Connected Cable
|
|
1.5 mm²
|
- Number/Type of Cable Glands
|
|
6 pcs / WKM-M24 Φzk (9–15)
|
- Dimensions Without Cable Glands and Power Supply (W × H × D)
|
|
380 × 250 × 160 mm
|
- Overall Dimensions (W × H × D)
|
|
380 × 358 × 160 mm
|
|
|
|
Approx. 13.5 kg
|
- Enclosure Protection Rating
|
|
IP65
|
|
Environmental Conditions for Fiber Optic Ethernet Interface
|
|
|
|
+5 to +40°C
|
- Relative humidity (non-condensing)
|
|
< 95% at 40°C
|
|
|
|
700–1060 hPa
|
|
|
|
Any
|